Rinko Akamine, Naomi Miyamoto, Shoko Kiritoshi, Mami Kusaka, Masayuki Akimoto
Osaka Red Cross Hospital, Osaka, Japan
Correspondence: Masayuki Akimoto
Osaka Red Cross Hospital, 5-30 Fudegasakicho, Tennojiku, Osaka, 543-8555, Japan
Email [email protected]
Background: We previously reported a novel technique using an elastic silicone bowl, which was handmade from a phaco test chamber, to salvage dislocated lenses and perform phacoemulsification and aspiration (PEA) on the bowl. However, creating the bowl was challenging.
Methods: A factory-made elastic silicone sheet (ESS), a ready-to-use alternative for the posterior capsule of the lens, was prepared. We used this sheet to salvage and support the dislocated/subluxated lenses in 11 eyes of nine patients.
Results: We could use a sheet immediately after we opened the package. In all the cases, we could insert a sheet beneath the lens and PEA performed at the center of the operative field. There was only one incident where the lens could not be placed onto the disc at the first attempt, but the lens was eventually salvaged. There was no risk of rupture during PEA, and the ESS could be removed completely without any complications.
Conclusion: The factory-made ESS described here can be used for salvaging dislocated/subluxated lenses and safely performing PEA.
Keywords: lens dislocation, perfluorocarbon, alternative posterior capsule of the lens
This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License.
By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.